1 / 9
1 / 9
Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A
Article: AK667806--
47 310 ₸
To order
An automatic circuit breaker with integrated residual current device (RCD) designed to protect electrical circuits from overloads, short circuits, and earth leakage currents. The device provides reliable protection in residential and commercial electrical installations.
Key Characteristics:
- Rated Current: 6 A
- Number of Poles: 3+N (three-phase + neutral)
- Rated Differential Current Sensitivity (IΔn): 30 mA
- Type A: selective to pulsating DC current, applied in circuits with electronic devices
- Breaking Capacity: 6 kA
- Trip Characteristic: C (designed for protection of distribution networks and long cable lines)
- Operating Speed: immediate disconnection upon activation
Operating Conditions:
- Operating temperature range: -25°C to +60°C
- Power loss at rated current: 3.23 W
- Mounting depth: 77 mm (standard for DIN rail)
Standards Compliance:
The device complies with international standards EN 61009-1:2012 and its amendments (A1:2014, A2:2014, A11:2015, A12:2016), as well as EN 61009-2-1:1994 + A11:1998 and IEC 61009-1, IEC 61009-2-1, ensuring a high level of safety and reliability.
Dimensions and Weight:
- Width: 71 mm
- Height: 85 mm
- Depth: 77 mm
- Net Weight: 0.42 kg
The device is part of the AMPARO series by Schrack, a manufacturer renowned for the quality and reliability of electrical equipment.
| EAN Code | 9004840666755 |
|---|---|
| Width Net | 71.00 mm |
| Height Net | 85.00 mm |
| Depth Net | 77.00 mm |
| Net Weight | 0.42 kg |
| Power Loss | 3.23 W |
| Min. Ambient Temperature | -25°C |
| Max. Ambient Temperature | 60°C |
| Standard | EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016, EN 61009-2-1:1994 + A11:1998, IEC 61009-1, IEC 61009-2-1 |
| Type | A (sensitive to pulsating current) |
| Type | immediate disconnection |
| Rated Sensitivity IΔn | 30 mA |
| Characteristic | C |
| Poles | 3+N |
| Breaking Capacity | 6 kA |
| Series | AMPARO |
| Manufacturer | Schrack |
| Packaging | 1 pcs., 45 pcs. |
- Photo 1: Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A (JPG, 353 KB)
- Photo 2: Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A (JPG, 333 KB)
- Photo 3: Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A (JPG, 403 KB)
- Photo 4: Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A (JPG, 366 KB)
- Photo 5: Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A (JPG, 425 KB)
- Photo 6: Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A (JPG, 331 KB)
- Photo 7: Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A (JPG, 392 KB)
- Photo 8: Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A (JPG, 342 KB)
- Photo 9: Automatic Circuit Breaker with Residual Current Device C6A/3+N, 6kA, 30mA, Type A (JPG, 390 KB)